Turn your heating load into the allowed furnace output range and the input rating you will see on a spec sheet.
How it works
Start with a Manual J design heating load. Manual S allows furnace output between 100% and 140% of that load. Dividing output by AFUE gives input.
Before you order
- Get a real load calculation. Rules of thumb per square foot commonly oversize furnaces.
- A furnace too large short-cycles and runs less efficiently.
- Airflow, duct size and venting matter as much as the BTU number.
Common questions
What is the difference between input and output?
Input is the fuel burned. Output is the heat delivered. An 80% AFUE furnace turns 100,000 BTU input into about 80,000 BTU output.
Can I just match my old furnace?
Old furnaces are often oversized, and insulation or window changes alter the load. Have the load calculated first.